We're here when you need us: |
: |
: |
: |
: |
Products Detail:
The safety-related F3 DIO 16/8 01 remote I/O is a compact system in a metal housing with 16 digital inputs, 8 2-pole digital outputs and 2 pulsed outputs. |
||||
F3 DIO 16/8 01Data sheet |
The 2-pole outputs consist of 2 switches connected in series, one switching to L+ and the other switching to L-. |
|||
The remote I/O is available in various model variants for SILworX and ELOP II Factory. |
||||
They are used to extend the I/O level, but are not able to run any user program by themselves. |
||||
Parts delivered worldwide |
Award-winning service |
More than 25 in stock |
Full 12-month warranty |
We deliver worldwide |
The safety-related F3 DIO 16/8 01 remote I/O is a compact system in a metal housing with16 digital inputs, 8 2-pole digital outputs and 2 pulsed outputs. The 2-pole outputs consist of2 switches connected in series, one switching to L+ and the other switching to L-.The remote I/O is available in various model variants for SILworX and ELOP II Factory, seeTable 4.
Remote I/Os are connected to individual HIMax or HIMatrix controllers via safeethernet. Theyare used to extend the I/O level, but are not able to run any user program by themselves.
The remote I/O is suitable for mounting in Ex-zone 2, see Chapter 4.1.6.The device is TÜV-certified for safety-related applications up to SIL 3 (IEC 61508, IEC 61511and IEC 62061), Cat. 4 and PL e (EN ISO 13849-1) and SIL 4 (EN 50126, EN 50128 andEN 50129).
Further safety standards, application standards and test standards are specified in thecertificates available on the HIMA website.
Safety Function
The remote I/O is equipped with safety-related digital inputs and outputs. The input values onthe inputs are safely transmitted to the connected controller via safeethernet. The outputs aresafely assigned their values by the connected controller via safeethernet.
Reaction in the Event of a Fault
If the device detects a fault on a digital input, the user program processes a low level inaccordance with the de-energized to trip principle.
The device activates the FAULT LED.
In addition to the channel signal value, the user program must also consider the correspondingerror code.
The error code allows the user to configure additional fault reactions in the user program.
8
Your concern point |
1. All products we sold arewith 100% New original packaged |
2. One year warranty |
3. International express |
4. Fast response |
5. Professional after-sales service |
Our company's products are all genuine imported goods from abroad, which can be tested, worry-free after-sales service, and quality guaranteed.
We have tens of thousands of models and tens of thousands of stocks in stock, welcome to consult!
*Direct purchase from abroad, genuine products, preferential prices, after-sales warranty, complete models, and advantageous inventory.
*All spare parts have a warranty period of 1 year and are professionally tested and certified.
*If you need to order more than 1 product, please contact us and we can provide you with a discount.
*If you find that other suppliers offer lower prices for the same products, we are also willing to provide you with further discounts based on their prices.
*If you have any other questions, please feel free to contact us.
*Please let us know if you have any needs for spare parts, and we can provide you with further assistance. We are waiting for your inquiries.
*Same product, different price and service.
*Your choice is our driving force.
Main business: PLC and DCS system spare parts modules of world-renowned brands, superior supply, sufficient inventory
Foxboro: I/A Series system, FBM full series (field input/output module)
Sequential control, ladder logic control, accident recall processing, digital-to-analog conversion, input/output signal processing,
Data communication and processing, etc.
Westinghouse: 1C31 series DCS system, CPU, OVATION system, WDPF system,
WEStation system spare parts.
Triconex: Redundant fault-tolerant control system, modern fault-tolerant controller based on triple modular redundancy (TMR) structure.
EMERSON: Modules, cards, drives and other spare parts.
XYCOM: XVME series
Bently: 3500/3300 system.
Rockwell: ICS system.
ABB: PM full range DCS system, IGCT high voltage inverter series, industrial robot spare parts DSQC series, INFI 90, etc.
Bailey: BRC series DCS system, etc.
Allen-Bradley: 1756, 1785, 1771, 1746 full range system, etc.
Yokogawa: CP series, etc.
Honeywell: TK/TC/CC systems, etc.
Reliance: 57C series, etc.
Schneider: 140 series processors, control cards, power modules, etc.
Modicon: AS series PLC system spare parts.
Siemens: 6ES5/6ES7414/6ES7415/6ES7416 series PLC system spare parts,
Siemens MOORE, Siemens Simatic C1, Siemens CNC system, etc.
Motorola: MVME 162, MVME 167, MVME1772, MVME177, etc.
XYCOM: I/O, VME board and processor, etc.
GE: IC698/IC697 full range of PLC systems, modules, cards, drivers and other spare parts.
Yaskawa: servo controller, servo motor, servo driver.
Bosch Rexroth: Indramat, I/O modules, PLC controller, drive module, etc.
Woodward: SPC valve position controller, PEAK150 digital controller.